FRO-203 RR Spo2 Pediatric Pulse Oximeter Ụlọ Jiri Pulse Oximeter
Njirimara ngwaahịa
Ụdị | nlekota ụlọ |
Otu | Pulse oximeter |
Usoro | Narigmed® FRO-203 |
ngwugwu | 1pcs / igbe, 60 igbe / katọn |
Ụdị ngosi | Uhie uhie |
Ngosipụta oke | SPO2 \ PR LED |
Oke nha SpO2 | 35% ~ 100% Ultra wide nso |
Ntụle SpO2 ziri ezi | ± 2% (70% ~ 100%) |
Oke nha nha PR | 25 ~ 250bpm Ultra wide nso |
Ntụle PR ziri ezi | Nke kachasị ± 2bpm na ± 2% |
Ọrụ mgbochi ngagharị | SpO2± 3% PR ± 4bpm |
Obere perfusion arụmọrụ | SPO2 ± 2%, PR ± 2bpm |
ọhụrụ oke | Oke ọhụrụ ahụ na-egosi ike nke perfusion PI |
Index nke perfusion | 0.02% ~ 20% |
Ọnụọgụgụ iku ume | 4rpm ~ 70rpm |
Oge mbupụta/oge ntule | 4s |
Mmechi akpaaka | Gbanyụọ ma mkpisi aka kwụsịrị 8s akpaaka n'ime sekọnd 8 |
Nkasi obi | Mpempe mkpịsị aka nke oghere silicone, enwere ike eyi nke ọma ogologo oge |
plethysmogram | EE |
Gbanwee ntụzịaka ngosi | Mgbanwe aka na ndabara, enwere ike ịhazi ntụgharị akpaka |
Ọkwa batrị dị ala | EE |
Na-elele data akụkọ ihe mere eme | EE |
Ihe ncheta enyemaka ahụike | EE |
irradiance nwere ike imezi | Enwere ike idozi nchapụta ihuenyo ahụ |
Oriri ike a na-ahụkarị | <30mA |
Arọ | 54g (ya na akpa na-enweghị batrị) |
Dismension | 62mm * 35mm * 31mm |
Ọnọdụ ngwaahịa | Ngwaahịa nke onwe-mepụtara |
Voltaji - ọkọnọ | 2 * 1.5V AAA batrị |
Okpomọkụ na-arụ ọrụ | 5°C ~ 40°C 15% ~ 95% iru mmiri 50kPa ~ 107.4kPa |
nchekwa gburugburu | -20°C ~ 55°C 15% ~ 95% iru mmiri 50kPa ~ 107.4kPa |
![FRO-203 RR Spo2 Ọrịa Ụmụaka Oximeter01](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter01.jpg)
![FRO-203 RR Spo2 Pediatric Pulse Oximeter02](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter02.jpg)
![FRO-203 RR Spo2 Pediatric Pulse Oximeter03](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter03.jpg)
Atụmatụ ndị na-esonụ
![FRO-203 RR Spo2 Pediatric Pulse Oximeter15](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter15.jpg)
![FRO-203 RR Spo2 Pediatric Pulse Oximeter11](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter11.jpg)
![FRO-203 RR Spo2 Pediatric Pulse Oximeter13](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter13.jpg)
![FRO-203 RR Spo2 Pediatric Pulse Oximeter06](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter06.jpg)
1. Ntụnye nkenke dị elu n'okpuru obere perfusion.N'okpuru ọnọdụ perfusion na-adịghị ike yana PI = 0.025%, nha oxygen ọbara Narigmed bụ SpO2 ± 2%.
2. Mgbochi mmega ahụ, nha nha nha nha nha bụ ± 2bpm n'okpuru ọnọdụ mmega ahụ
3. Mpempe mkpịsị aka na-ekpuchi silicone zuru oke, dị mma na enweghị mkpakọ
4. agbakwunyere ọnụego iku ume (RR) mmepụta ngwa ngwa (ndụmọdụ: dị na CE na NMPA).
5. Na-egosipụta ọrụ ntụgharị ihuenyo.
6. Health Asst (Health Status Report): Enwere obere anya na ihuenyo nke na-egbuke egbuke kwa sekọnd asatọ na nkeji nke 10 ruo 12 sekọnd.Mgbe obere anya anaghị enwu, pịa ma jide bọtịnụ ike ka ịbanye ọrụ nyocha ahụike ozugbo, nke ga-eme ka a na-enyo enyo hypoxia ma ọ bụ oke obi.Biko chere ka ị gwa onye ahịa ọkwa.
7. Ụlọ ọgwụ nwere ike ime ya, na akwụkwọ ndebanye aha
Otu dị mkpa
![FRO-203 RR Spo2 Pediatric Pulse Oximeter12](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter12.jpg)
![FRO-203 RR Spo2 Pediatric Pulse Oximeter14](http://www.narigmed.com/uploads/FRO-203-RR-Spo2-Pediatric-Pulse-Oximeter14.jpg)
Ndị na-arịa ọrịa Parkinson, ndị bi na mpaghara ala dị larịị, ndị na-ekesa ọbara na-adịghị mma, ndị okenye na ụmụaka, ndị nwere akpụkpọ ahụ gbara ọchịchịrị, wdg.